Solution Description
It is utilised to examination insulation performance for insulation gloves, boots, rod, Electroscope and so forth.
It can take a look at 6pcs insulation gloves/boots at the very same time, also 5pcs insulation rods
Functions
Guide manage unit
- Digital and real time exhibit HV voltage, LV present.
- With movable manage device, straightforward wiring and testing.
- Manual handle, safety and dependability.
- With zero, power, operation, timing indicators.
- With in excess of-present defense, zero-start defense, seem and mild alarm, electricity protected switch.
- New kind timer, broader timing selection.(1s-99h)
Other features
- HV supply is oil immersed kind screening transformer.(dry variety and SF6 fuel kind for alternative.)
- It is ideal for screening insulation gloves(boots), 6-10kV insulation rod.
- To make check for insulation gloves and boots, the HV electrode is chain kind, which the top can be modified. The substance is stainless metal with CU/EpNi5bc painted, which make area discharge<10pc. 6pcs insulation barrels are also supplied.
- The electrode of insulation boots is red cooper voltage-sharing variety, the HV within the bottom of boots are equivalent distribution. 4mm metal balls equipped, not using traditional way that injecting h2o.
- With insulation rod stand to make withstand voltage and leak test for insulation rod.
- Management unit and HV device are individual, to ensure security.
- If there is breakdown or above limitations, the HV output will be lower off instantly and alarm.
Specs
Rated potential | 10kVA |
Enter voltage | AC220V±10%, 50Hz±1 |
Output voltage | -50kV |
Voltage accuracy | ≤ two.%(F.S) |
LV recent | -50A |
Leak current | -thirty.0mA |
Resolution of leak current | .1mA |
Present accuracy | ≤1.five% |
Timing range | -99h |
Environmental temperature | -20ºC-50ºC |
Other Technical specs for electroscope, insulation rod, mat take a look at and so forth.
Insulation Rod | |||||
Voltage (kV) | Interval distance of electrode mm | Check voltage (kV) |
Check size (m) |
Time (min) | Testing stand |
ten | 400 | forty five | .7 | one | GDJ-50 |
35 | 600 | ninety five | .9 | 1 | GDJ-fifty, GDJ-one hundred |
63 | seven-hundred | 175 | 1. | one | GDJ-a hundred, GDJ-200 |
one hundred ten | one thousand | 220 | one.3 | 1 | GDJ-200, GDJ-three hundred |
220 | 1800 | 440 | two.1 | one | GDJ-three hundred (segment) |
330 | 2800 | 380 | 3.two | 5 | GDJ-two hundred (part) |
five hundred | 3700 | 580 | four.one | 5 | GDJ-300 (segment) |